3 PHASE 60 HERTZ, CLASS OA/FA, 6.94% IMPEDANCE, 55/65 DEG C RISE, COPPER WINDINGS, TOP-TOP HV AND LV BUSHINGS, LIQUID LEVEL TEMPERATURE GAUGE, PRESSURE VACUUM GAUGE, PRESSURE RELIEF DEVICE, WINDING TEMPERATURE INDICATOR HIGH VOLTAGE: 67000 DELTA BIL: 350 KV LOW VOLTAGE: 12470Y/7200 BIL: 110 KV** TAPS: 70600-68800-67000-65200-63400 TOTAL WEIGHT: 55,807 LBS. CORE & COILS: 26,852 LBS. TANK & FIT.: 8,319 LBS. RADIATORS: 4,606 LBS. ***TANK OIL: 14,549 LBS. (1,940 GALS.) ***RADIATOR OIL: 1,481 LBS. (197 GALS.) No. 1 CTG-3876/44483 / No. 2 CTG-3844/44003 10/12.5/11.2/14.0 MVA KUHLMAN SUBSTATION TRANSFORMER Reconditioned with (1) Year Warranty
JSHP TRANSFORMER CO. LTD. UNUSED DE-ENERGIZED TAP CHANGER TYPE TRANSFORMER 112 MVA 138 kVD – 34.5 kVY 60HZ 3-PHASE OUTDOOR TRANSFORMER HV: 138000 VBOLTS XV: 34500GRDY/19918 VOLTS HV: 112.5/150/187.5 MVA CONT. TEMP. RISE 65°c XV: 112.5/150/187.5 MVA CONT. TEMP. RISE 65°c CODE NO. ANSI C57.12.00 2015 CLASS: ONAN/ONAF1/ONAF2
New 60/80MVA 60Hz. 3-Phase Step Down Transformer HV: 69 kV LV : 34.5 kV Winding Type: Copper Function: Step-Down
ONE (1) 30/33.6/40/44.8/50/56 MVA WAUKESHA, GENERATOR STEP-UP TRANSFORMER, 3 PHASE, 60 HERTZ, CLASS ONAN/ONAF/ONAF, 55/65 DEG. C RISE, 9,69% IMPEDANCE, COPPER WINDINGS, 6 X HV 600:5, MRCT'S C800, 6 X LV 1200:5 MRCT'S C800, CONSERVATOR, MFG. 2003 HIGH VOLTAGE: 138000GRDY/79670 BIL: 650 KV LOW VOLTAGE: 34500GRDY/19920 BIL: 200 KV TERTIARY: 12470 VOLTS BIL: 110 KV TAPS: 144900-141450-138000-134550-131100 Full reconditioned with (1) year warranty
THREE PHASE, 60 HERTZ, CLASS OA/FA/FOA IMPEDANCE 7.01%, 65 C RISE, ALUMINUM WINDINGS TOP-TOP BUSHINGS, WINDING TEMPERATURE GAUGE, CT's 600:5 RATIO DRAIN & SAMPLE VALVE, LIQUID LEVEL GAUGE, LIQUID TEMPERATURE GAUGE HV: 138000 DELTA BIL: 650 kV LV: 13800 WYE BIL: 110 kV HV Taps: 144900-141450-138000-134450-13110 Fully Reconditioned with (1) Year Warranty
ONE (1) UNUSED SURPLUS 5000 KVA LIQUID FILLED TRANSFORMER DATA: • MOD/SN: 425000A006W • KVA: 5000 AT 65°C RISE • 3 PHASE, 60 Hz, 65'C RISE CLASS: KNAN • IMP: 5.75 ± 7.50 % • TAPS: ± 2 X 2.5 % NOM. • HV: 4160GrdY/2402, 60 kV BIL, 694 A NOM @5000 KVA LV: 600 DELTA, 45 kV BIL, 4810 A @5000 KVA • WT: 28,900 LBS WINDINGS: ALUMINUM
• 3-Phase Substation Transformer • High Voltage: 67000 D, 350 kV BIL • Low Voltage: 12470 Y 7200, 110 kV BIL • Taps: 70600, 68800, 67000, 65200, 63400 • HV Bushings: (3) Stud (Threaded) • HV Termination: Exposed/Top ANSI 3 • LV Bushings: (3) Stud (Threaded) • LV Termination: Exposed/Top ANSI 1 • LV Neutral Bushings: (1) Stud (Threaded) • LV Neutral Termination: Exposed/Top ANSI 1 • Fluid: Mineral Oil • Frequency: 60 Hz • Temperature Rise: 65°C • Cooling Class: ONAN/ONAF • Conductor: Al / Al
Rating (KVA): 108/144/180 MVA Frequency: 60Hz. Windings: Copper Primary Voltage: 335 KV Secondary Voltage: 34.5 KV Vector Group: YNyn0+d1 Phases: 3 65° C Rise ONAN/ONAF1/ONAF2 Oil Preservation Systems: Conservator Manufacturer: Georgia Transformer Corp. Location: Southeast USA Standards: IEEEC57.12.00 (2015) Warranty: 5 Years Available: 1 unit Price: Call For Specifications and Price Documentation folder available for your review (serious inquiries only): 1. Comprehensive Drawings. 2. Nameplate 3. Photos
3 PHASE, 60 HERTZ, CLASS ONAN/ONAF/ONAF/ONAF 55/65 DEG. C RISE, 9.43% IMPEDANCE, COPPER WINDINGS HV TOP MOUNTED BUSHINGS, CONSERVATOR, HIGH VOLTAGE: 138000GRDY/79670, BIL: 550 KV LOW VOLTAGE, 13800 DELTA, BIL:110 KV, TAPS:144900-141450-138000-134550-131100 Fully Reconditioned Call for Quote. Serious Inquiries Only Please.
• Frequency: 60 Hz • Cooling Class: ONAN/ONAF/ONAF • Impedance: 9.59% • Temperature Rise: 65°C • Windings: Copper Additional Features: • Liquid Level Gauge • Electronic Temperature Monitor • Pressure Release Device • Pressure Vacuum Bleeder • Pressure Gauge • Sudden Pressure Relay High Voltage (HV): 138,000 Delta BIL: 450 kV Low Voltage (LV): 13,200 GRDY/7,620 BIL: 110 kV Taps: 144,900-141,450-138,000-134,550-131,100